Modine Natural Gas 400/320K BTU Horizontal Separated Combustion Aluminized Heat Exchanger
Item No. 34065000
Separated Combustion Gas-Fired Unit Heaters Commercial Gas-Fired Heaters - 400/320K BTU Modine�s PTS/BTS separated combustion unit is specifically designed for environments with hostile atmospheric conditions, such as chemicals, high humidity, or negative pressure. On these units, combustion air is
Price $5290
price per EACH
Contact Us For Availability
EACH
Description
Separated Combustion Gas-Fired Unit Heaters
Commercial Gas-Fired Heaters - 400/320K BTUModine�s PTS/BTS separated combustion unit is specifically designed for environments with hostile atmospheric conditions, such as chemicals, high humidity, or negative pressure. On these units, combustion air is brought in from outside the heated area, either from outdoor air or from an adjacent room, eliminating the need to use contaminated indoor air for combustion.
- In-shot burners fire each heat exchanger tube for reliable performance, ease of service, and decreased noise on ignition.
- Same-size vent and combustion air inlets make installation easier.
- Longer allowable vent lengths (up to 50? vs 30?) providing greater installation options.
- Round vent pipe and combustion air inlet pipe connection
- Automatic reset vent pressure switch is designed to prevent operation of the main burner in the event there is restricted venting of the flue
- Integrated direct spark control board provides digital control of the air mover, inducer, ignition, gas valve, and flame sense
- Control Step Down Transformer used to step down from 115v to 24v for the gas controls, fan delay relay, field-supplied motor start, and more.
- Remote flame sensor verifies ignition of all burners, monitors the flame single, and communicated with the integrated circuit board
- The high limit control switch is mounted in the air stream and will shut off the gas supply in the event of overheating
- Designed, Engineered & Assembled in the USA
- Vertical Deflectors Blades
- 30, 60 and 90 degree air deflector hoods
- Horizontal Concentric Vent Kit
- Pipe Hanger Adapter Kits
- Natural Gas to Propane Gas Conversion Kits
- Single or Two-Stage Room Thermostats
- Room Thermostat Guard
- Stepdown Transformers
- Controls Relays
Installation & Service Manual, PTS/BTS
Unit Heater Maintenance Checklist
Warranty Overview
Things To Consider
- How many BTU�s do they need?
- What type of heater do they need? (Natural Gas, Electric, Propane)
- Do they have 240V power? Do they have Phase I or Phase 3 power?
- Do they need a vent stack for separated combustion?
- Do you need a thermostat or controller?
- How are they circulating or moving heat in the space?
BTUs | ||||
Item # | Item Description | Input | Output | Modine Manu. # |
Modine Natural Gas 150/120K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 150000 | 120000 | PTS150SS0111SBAN | |
Modine Natural Gas 175/140K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 175000 | 140000 | PTS175SS0111SBAN | |
Modine Natural Gas 200/160K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 200000 | 160000 | PTS200SS0111SBAN | |
Modine Natural Gas 250/200K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 250000 | 200000 | PTS250SS0111SBAN | |
Modine Natural Gas 350/280K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 300000 | 240000 | PTS300SS0111SBAN | |
Modine Natural Gas 300/240K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 350000 | 280000 | PTS350SS0111SBAN | |
34065000 Â | Modine Natural Gas 400/320K BTU Horizontal Separated Combustion Aluminized Heat Exchanger | 400000 Â | 320000 Â | PTS400AS0111SBAN Â |
Specifications
- SIZE
- 400/320K BTU 115V
Reviews (0)
There are no reviews yet.
Modine Natural Gas 400/320K BTU Horizontal Separated Combustion Aluminized Heat Exchanger
Item No. 34065000
Separated Combustion Gas-Fired Unit Heaters Commercial Gas-Fired Heaters - 400/320K BTU Modine�s PTS/BTS separated combustion unit is specifically designed for environments with hostile atmospheric conditions, such as chemicals, high humidity, or negative pressure. On these units, combustion air is
Price $5290
price per EACH
Contact Us For Availability
EACH
Description
Separated Combustion Gas-Fired Unit Heaters
Commercial Gas-Fired Heaters - 400/320K BTUModine�s PTS/BTS separated combustion unit is specifically designed for environments with hostile atmospheric conditions, such as chemicals, high humidity, or negative pressure. On these units, combustion air is brought in from outside the heated area, either from outdoor air or from an adjacent room, eliminating the need to use contaminated indoor air for combustion.
- In-shot burners fire each heat exchanger tube for reliable performance, ease of service, and decreased noise on ignition.
- Same-size vent and combustion air inlets make installation easier.
- Longer allowable vent lengths (up to 50? vs 30?) providing greater installation options.
- Round vent pipe and combustion air inlet pipe connection
- Automatic reset vent pressure switch is designed to prevent operation of the main burner in the event there is restricted venting of the flue
- Integrated direct spark control board provides digital control of the air mover, inducer, ignition, gas valve, and flame sense
- Control Step Down Transformer used to step down from 115v to 24v for the gas controls, fan delay relay, field-supplied motor start, and more.
- Remote flame sensor verifies ignition of all burners, monitors the flame single, and communicated with the integrated circuit board
- The high limit control switch is mounted in the air stream and will shut off the gas supply in the event of overheating
- Designed, Engineered & Assembled in the USA
- Vertical Deflectors Blades
- 30, 60 and 90 degree air deflector hoods
- Horizontal Concentric Vent Kit
- Pipe Hanger Adapter Kits
- Natural Gas to Propane Gas Conversion Kits
- Single or Two-Stage Room Thermostats
- Room Thermostat Guard
- Stepdown Transformers
- Controls Relays
Installation & Service Manual, PTS/BTS
Unit Heater Maintenance Checklist
Warranty Overview
Things To Consider
- How many BTU�s do they need?
- What type of heater do they need? (Natural Gas, Electric, Propane)
- Do they have 240V power? Do they have Phase I or Phase 3 power?
- Do they need a vent stack for separated combustion?
- Do you need a thermostat or controller?
- How are they circulating or moving heat in the space?
BTUs | ||||
Item # | Item Description | Input | Output | Modine Manu. # |
Modine Natural Gas 150/120K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 150000 | 120000 | PTS150SS0111SBAN | |
Modine Natural Gas 175/140K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 175000 | 140000 | PTS175SS0111SBAN | |
Modine Natural Gas 200/160K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 200000 | 160000 | PTS200SS0111SBAN | |
Modine Natural Gas 250/200K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 250000 | 200000 | PTS250SS0111SBAN | |
Modine Natural Gas 350/280K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 300000 | 240000 | PTS300SS0111SBAN | |
Modine Natural Gas 300/240K BTU Horizontal Separated Combustion Stainless Steel Heat Exchanger | 350000 | 280000 | PTS350SS0111SBAN | |
34065000 Â | Modine Natural Gas 400/320K BTU Horizontal Separated Combustion Aluminized Heat Exchanger | 400000 Â | 320000 Â | PTS400AS0111SBAN Â |
Specifications
- SIZE
- 400/320K BTU 115V
Reviews (0)
There are no reviews yet.